New generation
heating systems
Address: 2, Vaclav Havel Blvd
(2, Ivana Lepse Blvd)
03067, Kyiv, Ukraine,
Phones: (096) 457 39-39
(099) 457 39-39
(073) 457 39-39

Single phase

Specifications

Power - 1-phase network, 50 Hz 1 х 220V, 50 Hz
Thermal power of the heating systems 3…9 kW
Power of one heating module (heating stage) 3 kW, 4 kW, 5 kW, 6 kW
Number of heating modules 1…3
Range of regulation of temperature of the return heat carrier +15 оС … +60 оС
Maximum flow temperature +75 оС
Dimensions of the heating module 1150 х 140 х 140 mm
Overall dimensions of the thermostat 320 х 250 х 150 mm
Overall dimensions of the control panel 10-step system 2000 х 1000 х 400 mm
Mass of the heating element 15 kg
Productivity of the circulation pump in one module calculated, not less 1,0 m3/hour

Advantages of the SOLMA system

  • The modular design of the SOLMA system makes it possible to create from standardized heating modules of a heating system with a capacity from 3 kW to 9 kW that best suits the needs of the customer.
  • The step regulation and the priority limiting of the heating power with the number of heating stages to 3 limits the current load and prevents the power limit from exceeding.
  • The simplicity of the design with the highest possible efficiency and a large area of ​​stainless steel heat exchanger provide the highest reliability and durability and, as a result, significant cost savings for consumers over the entire life cycle.
  • Silent execution provides an unlimited number of switching cycles and the ability to place the thermostat of the SOLMA system in domestic premises without sacrificing comfort.
  • An unprecedented amount of protection levels makes the SOLMA system one of the safest on the market.
  • The low weight, compact size and ease of installation of the SOLMA heating modules significantly reduce the commissioning time and also allow the equipment to be placed in small rooms.
  • The ability to service or replace heating modules without draining coolant and shutting down the system reduces operational costs.
  • Due to the small volume of the heating zone of the heating module, the heated coolant enters the system after a very short time - a few seconds - which reduces the time for the user to “wait for heat”.
  • Daily and weekly programming of heating, taking into account tariff zones and in combination with heat accumulators and multi-tariff metering of electricity, provides significant savings compared with other types of heating and DHW and evens out daily electricity load schedules.
  • Having a data port allows you to integrate SOLMA into Smart Home systems.